+91 44 43500300 9:30 - 18:30hrs (Monday-Friday) KRM Towers, Harrington Road, Chetpet, Chennai - 600031.
+91 44 43500300 9:30 - 18:30hrs (Monday-Friday) KRM Towers, Harrington Road, Chetpet, Chennai - 600031.

ZT100 S-Series

The iso-kinetic S-Series provides reliable water content metering in all small pipe applications. The ZT-100 S-Series of Watercut Meters can be installed inline or in bypass. Built to any piping spec in the materials of your choice. For larger pipes also check out the F-Series and the new I-Series of water cut meters.

The ZelenTech ZT-100 Watercut Monitor determines the percent watercut in an oil emulsion without requiring the physical separation of the fluids. The emulsion stream is continuously monitored for capacitance and converted into percentage of water by the Watercut Monitor logic.

ZelenTech ZT-100 Watercut Monitors (also known as BS&W, OWD, WFM or Water in Oil Analyzers) offers you unmatched flexibility as we offer virtually unlimited number of configurations.

Description

ZelenTech ZT-100 Watercut Meters (BS & W, OWM)

Features

  • Automatic Temp Comp
  • Optional Density Comp
  • HART + Modbus available
  • PC Interface

S-SERIES SPECIFICATIONS

Parameter Value
Response time 1 sec
Sensitivity 0.01%
Repeatability 0.1%
Output 4-20mA + HART
Power Supply 24VDC (Loop Powered)
Power Consumption 0.66W Max
Temperature (Media) +150° C (250 with High Temp Option)
Temperature (Ambient) +60° C
Ingress Protection IP66
Measurement Range 0-25% or 0-100%
Nominal Sizes 1 to 6 inch or DN25 to DN200
Material (Standard) 316L
Seals and electrical insulators PEEK

S-SERIES GENERAL DATA

Parameter Value
Principle of Operation High Frequency Digital Capacitance
Resolution (Low Range) 0.001%
Accuracy (Low Range) 0.01%
Resolution (High Range) 0.05%
Accuracy (High Range) 0.05%
Repeatability 0.01% Absolute
Max Water (Low Range) 25%
Max Water (High Range) 100%
Temp Compensation Range >0°C – 180°C

S-SERIES MECHANICAL DATA

Parameter Value
Wetted Steel Material 316L Standard (More exotic materials available)
Seals PEEK
Max. Working Pressure Up to Class 1500#
Max. Fluid Temperature 180°C Standard (240°C Optional)
Max. Ambient Temperature 65°C
Process Connection ANSI, DIN, JIS

S-Series Configurations and Features

Threaded or Flanged Models:

  • Slip-On Flanges or Weld Neck Flanges.
  • ANSI, DIN or JIS Flanges
  • Flange sizes from 1 inch to 8 inch
  • NPT, BSP, BSPT
  • Threaded sizes from 1 inch to 3 inch

Measurement Ranges:

  • Low Range 0-25%
  • Mid Range 0-65%
  • High Range 0-100%

Design Features:

  • Isokinetic Inline Sensor
  • 2-wire Loop powered
  • Temperature Compensation
  • Optional Density Compensation

INTEGRATED STATIC MIXER

The ZelenTech ZT-100 S-Series can optionally be fitted with an integrated Static Mixer (SM-Series). The mixer will ensure that a well mixed and homogenized stream will reach the sensor. We configure mixer elements and spacing in accordance with standards such as ISO 3171 and API MPMS8.2 to ensure that the sensor will see a truly representative view of what is going on in your pipes.