The FAURE HERMAN FH8300 Ultrasonic Flowmeter is designed to measure liquids – both conductive and non-conductive. Thanks to its variety of digital and analog inputs/outputs , the FH8300 is a versatile flowmeter
which easily interfaces with any process management system.
Key Technological Features
• Curve linearization
• High measurement repeatability
• Bi-directional measurement
• No pressure drop
• Communication
• Removable transducers under
pressure and flowing conditions
Key Customer Advantages
• Extended turndown ratio
• Lower cost of ownership
• Simplified maintenance
• Simple integration into existing systems
• Measurement of all liquids
• Process integrity
• Easily cleaned
FH8300 Configurations
1.FH8300-1
• 1 beam
• ± 1 % accuracy
• DN 50 to DN 600 (2” to 24”)
2.FH8300-2
• 2 beams
• ± 0.5 % accuracy
• DN 80 to DN 600 (3” to 24”)
• anti-swirl effect
• extended dynamic range
3.FH8300-3
• 3 beams
• ± 0.25 % accuracy
• DN 100 to DN 600 (4” to 24”)
• anti-swirl effect
• flow profile compensation
(multi-product)
Environment
Ambient temperature range -40 to + 60° C(-40 to+140° F)
Process range -40 to + 120 °C (- 40 to+248°F)
Storage temperature -40 to + 60 °C (- 40 to+140°F)
Climatic protection IP 66 / NEMA 4X
Safety : ATEX II 2 G
Transducer classification Ex d IIB T6 to T3 / LCIE 04 ATEX 6047X
Enclosure classification Ex d IIB T6 / LCIE 04 ATEX 6071 X
Remote control Ex ia IIC T4 / LCIE 03 ATEX 6240 X
Mechanical
Meter size DN 50 to DN 600 (2” to 24”) (higher upon request)
Maximum operating pressure 150 bar (2180 PSI)
Meter body material Carbon steel,Stainless steel,Other material upon request
Flanges ANSI 150/300/600/900
Transducers Removable under service conditions
Performances
Accuracy FH8300-1,FH8300-2,FH8300-3 – ±1 % (1 to 10m/s) ,±0.5 % (1 to 10m/s),±0.25 % (1 to
(Please refer to the tables paragraph “Measurement Principle and Operating Range”)
Repeatablity – ± 0.1 %
Minimum flow velocity detection – 0.005m/s
Viscosity range (Please refer to the tables paragraph “Measurement Principle andOperating Range”)
Density range – 400 to 1,500 kg/m3
Pressure drop -No pressure drop
Electronics
Power supply 18 to 36 Vdc 8W, or 100 to 250 Vac
Inputs 1 4-20 mA (pressure)
Outputs 1 or 2 off 4-20 mA (Flowrate and/or VOS), 1 or 2 off pulses with galvanic separation
Frequency 10Hz – 10 kHz with galvanic separation,1 or 2 dry contacts (Alarms)
Communications/Serial Link 1 RS 485(Modbus)(other person on request)
Software Configuration and analysis PC software FHview
Installation conditions
Standard 10 to 30D straight line upstream depending on flow conditions,
3D straight line dowstream
Options
LCD Local display 4 x 20 car. alphanumeric display
Data & Event logger Flowrates, VOS, Gain,…
Remote converter Distance < 5m
Calibration Multi-product
Approvals
ATEX 94/09/compliant
PED 97/23/EC & ASME compliant
EMC 2004/108/EC compliant