Simultaneous or as individual measurement: the GM35 gas analyzer measures CO2, H2O and CO, or N2O, as well temperature and pressure – and it does this reliably, quickly, and economically. As an in-situ gas analyzer, the GM35 detects these gas components directly in the gas stream without gas sampling. Reliability, precision, and short response time of the GM35 offer a key advantage for efficient control loops in all CO and CO2-generating processes.
| Measured values | CO, CO2, H2O, N2O | ||||||||||||
| Performance-tested measurands | CO, CO2, H2O | ||||||||||||
| Measurement principles | Gas filter correlation, Interference filter correlation | ||||||||||||
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
| Conformities | Approved for plants requiring approval
2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27.BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 MCERTS |
||||||||||||
| Electrical safety | CE | ||||||||||||
|
|||||||||||||
| Operation | Menu-driven operation via separate control unit | ||||||||||||
| Model | Cross-duct version
Measuring probe version |
||||||||||||
| Test functions | Automatic check cycle for zero and span point | ||||||||||||
| Description | Analyzer unit of the measuring system | ||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
| Description | Measuring probe in open design with integrated purge air control system | ||||
|
|||||
|
|||||
|
|||||
|
|||||
|
|||||
|
|||||
| Material in contact with media | Stainless steel 1.4571, stainless steel 1.4539 | ||||
|
|||||
| Integrated components | Pressure sensor
PT1000 temperature sensor |
||||
| Description | Measuring probe with gas permeable filter element for adjustment with test gas | ||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
| Material in contact with media | Stainless steel 1.4571, stainless steel 1.4539, ceramics, PTFE | ||||||||
|
|||||||||
|
|||||||||
| Integrated components | Pressure sensor
PT1000 temperature sensor |
||||||||
| Description | Reflector unit with hollow triple reflector | ||||
|
|||||
|
|||||
|
|||||
|
|||||
| Description | The evaluation unit serves as the user interface and is responsible for data processing and output as well as control and monitoring functions. | ||||||||
|
|||||||||
| Analog outputs | 3 outputs: 0/4 … 20 mA, 500 Ω Electrically isolated |
||||||||
| Analog inputs | 1 input: 0 … 20 mA, 100 Ω |
||||||||
| Digital outputs | 3 relay contacts: + 48 V AC, 1 A, 60 W / 48 V DC, 1 A, 30 W Preset for failure, maintenance and functional control |
||||||||
| Digital inputs | 3 inputs: + 24 V |
||||||||
|
|||||||||
|
|||||||||
|
|||||||||
| Input | Arrow keys
Functional keys |
||||||||
| Operation | Menu-driven operation via LC-display and membrane keyboard | ||||||||
| Model | Steel sheet enclosure | ||||||||
|
|||||||||
|
|||||||||
|
|||||||||
| Description | The evaluation unit serves as the user interface and is responsible for data processing and output as well as control and monitoring functions. | ||||||||
|
|||||||||
| Analog outputs | 3 outputs: 0/4 … 20 mA, 500 Ω Electrically isolated |
||||||||
| Analog inputs | 1 input: 0 … 20 mA, 100 Ω |
||||||||
| Digital outputs | 3 relay contacts: + 48 V AC, 1 A, 60 W / 48 V DC, 1 A, 30 W Preset for failure, maintenance and functional control |
||||||||
| Digital inputs | 3 inputs: + 24 V |
||||||||
|
|||||||||
|
|||||||||
|
|||||||||
| Input | Arrow keys
Functional keys |
||||||||
| Operation | Menu-driven operation via LC-display and membrane keyboard | ||||||||
| Model | Cast metal enclosure | ||||||||
|
|||||||||
|
|||||||||
|
|||||||||
| Description | To lengthen the internal CAN-Bus connection with cable provided by the customer | ||||
|
|||||
|
|||||
| Description | Fixture to flanges with connections for purge air and external cabelling | ||||
|
|||||
|
|||||
|
|||||
| Integrated components | PT1000 temperature sensor
Pressure sensor |
||||
| Description | Fixture to flanges with connections for purge air and external cabelling | ||||
|
|||||
|
|||||
|
|||||
| Description | Unit to provide dust-free air for flushing of optical surfaces | ||||||
|
|||||||
|
|||||||
|
|||||||
|
|||||||
|
|||||||
|
|||||||
|
|||||||
| Test functions | Pressure switch (switching point –35 hPa) | ||||||
| Integrated components | 2-step air filter, type Europiclon, dust capacity 200 g | ||||||