The MCS300P is an extractive process photometer for measuring gaseous or liquid media. It measures IR and VIS active components with variable measuring ranges from very low (ppm) to high (vol%) concentrations. For monitoring of toxic or flammable mixtures, it has special process cells with safety devices like twinseals and flushing gas feeds. The heatable cells made of corrosion-resistant materials have a high pressure resistance. Automatic adjustment, innovative operation concept and modern communication protocols make the MCS300P an all-purpose photometer, even for potentially explosive atmospheres.
| Measured values | Br2, CCl4, C2Cl4, CCl2F2, C3F6, CH4, C2H2, C2H4, C2H6, C3H4, C3H6, C3H8, C4H6, C4H8, C4H10, C6H6, C6H14, C7H8, CH3Cl, CH2Cl2, CHCl3, C2H3Cl, C2H2Cl2, C2H4Cl2, C2HCl3, C6H5Cl, C6H4Cl2, CHCl2F, CH3OH, C3H7OH, C2H4(OH)2, CH3CHO, HCOOH, CH3COOC2H3, C2H2O, Cl2, CO, CO2, COCl2, HCl, HCN, HF, H2O, NH3, NO, N2O, NO2, R-NCO, SO2, SiF4, many other IR / VIS active gases and liquids | ||||||||
| Measurement principles | Interference filter correlation, Gas filter correlation | ||||||||
|
|||||||||
| Measuring ranges | More than 60 measuring components available (depending on concentration and sample gas composition)
Up to 6 components simultanously 2 measuring ranges per component Automatic measuring range switching (adjaustable) 2 limit values per component Measuring ranges depend on application and combination of measuring components |
||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
| Electrical safety | CE | ||||||||
|
|||||||||
| Analog outputs | 2 outputs: 0/4 … 22 mA, 500 Ω Electrically isolated, max. number of outputs depends on application |
||||||||
| Analog inputs | 2 inputs: 0/4 … 22 mA, 100 Ω Electrically isolated, max. number of inputs depends on application |
||||||||
| Digital outputs | 5 outputs: 2 power relays, electrically isolated, 3 outputs, potential-free, max. number of outputs depends on application |
||||||||
| Digital inputs | 4 inputs: Open contacts, potential-free, max. number of inputs depends on application |
||||||||
|
|||||||||
|
|||||||||
|
|||||||||
| Input | Functional keys | ||||||||
| Operation | Via LC-display
Via software SOPAS ET (not in the Ex-version) |
||||||||
|
|||||||||
|
|||||||||
| Material in contact with media | Measuring cuvette depending on version | ||||||||
| Material | Aluminium, coated | ||||||||
|
|||||||||
|
|||||||||
| Corrective functions | Cross-sensitivity compensation of up to 6 interferents | ||||||||