TRANSIC100LP – O2 measurement in hazardous area environment

Combined measurement of dust, volume flow, pressure, and temperature

Measuring the oxygen in the process can be quite simple. The TRANSIC100LP from SICK is the rugged transmitter that uses Tunable Diode Laser Spectroscopy (TDLS) to measure O2 reliably.

Description

A technology more common in the world of high-tech analysis, is now being used in a field instrument: at an attractive price, easy installation, a long life, low-maintenance, and suitable for use in explosion-hazardous areas.

At a glance
Technical Specifications
Applications
Downloads

  • O2 transmitter based on high-performance laser spectroscopy (TDLS)
  • For use in use in explosion-hazardous areas (FM, ATEX and IECEx approvals)
  • Measurement directly in the process or extractive using a measurement gas cell (option)
  • Designed for heavy-duty industrial applications
  • Compact design and easy to operate
  • Long-term stability
  • No moving parts
Your Benefits
  • Measures in real-time directly in the process
  • Easy installation and operation
  • Self-diagnostics with maintenance display
  • Low requirements for gas conditioning
  • Low operating costs: no consumables and no purging gas consumption
  • Rugged: reliable measurement even in contaminated gases

Measured values O2
Measurement principles Diode laser spectroscopy (TDLS)
Measuring ranges
O2 0 … 5 Vol.-% / 0 … 100 Vol.-%
Response time (t90)
≤ 10 s
Accuracy
≤ 0.2 Vol.-%
Zero point drift
± 0.1 Vol.-%: per year
Process temperature
–20 °C … +80 °C
Process pressure
800 hPa … 1,400 hPa
Ambient temperature
–20 °C … +60 °C
Storage temperature
–30 °C … +80 °C
Ex-approvals
IECEx Sender/receiver unit: Ex ib IIB T4 Gb, Ex ib tb IIIC T85°C Db

Measuring probe: Ex op is IIB T4 Ga, Ex ib tb IIIC T85°C Db

TSA151 power supply: Ex e mb [ib] IIB T4 Gb, Ex tb [ib] IIIC T85°C Db

ATEX Sender/receiver unit: II 1/2G Ex ib IIB T4 Gb, II 2D Ex ib tb IIIC T85°C Db

Measuring probe: II 1/2G Ex op is IIB T4 Ga, II 2D Ex ib tb IIIC T85°C Db

TSA151 power supply: II 2G Ex e mb [ib] IIB T4 Gb, II 2D Ex tb [ib] IIIC T85°C Db

NEC/CEC (US/CA) Sender/receiver unit: Class I, Division 2, Group A, B, C, D T4

Measuring probe: Class I, Division 1 + 2, Group A, B, C, D T4

Electrical safety CE, FM
Enclosure rating
IP66
Analog outputs 1 output active:
0/4 … 20 mA, 500 Ω1 output active:
0/4 … 20 mA, 200 Ω
Only for ATEX/IECEx version TRANSIC151LP
Digital outputs 1 relay contact:
+ 30 V AC, 1 A / 60 V DC, 0.5 A1 NAMUR output:
Only for ATEX/IECEx version TRANSIC151LP
Serial
Remark Not for the ATEX/IECEx version
Type of fieldbus integration RS-232

RS-485

Function Proprietary service interface
USB
Remark Not approved for Ex-applications
Function Proprietary service interface
Dimensions (W x H x D)
See dimensional drawings
Weight
2.2 kg
Material in contact with media Stainless steel 1.4404 (AISI 316L), Kalrez®, EPDM, PTFE, SiN, MgF2, polymer coating
Mounting Flange for direct installation in the process

Wall-mounting bracket for ambient air measurement

Wall-mounting bracket for measurement with measuring gas cell

Power supply
Voltage 24 V DC

TRANSIC151LP: 21.6 … 26.4 V

For ATEX/IECEx version via TSA151 power supply, a PELV power supply is mandatory
Current consumption ≤ 500 mA

TRANSIC151LP: ≤ 240 mA

Power consumption ≤ 6 W

TRANSIC151LP: ≤ 5.2 W

Corrective functions Adjustment with ambient air or test gases
Test functions Contamination check

Fields of applications

  • Monitoring of inert gas blanketing in tanks and vessels
  • O2 measurement in process gases
  • Measurements in potentially explosive atmospheres
  • Process monitoring in fermenters and bioreactors
  • Room air monitoring
  • Quality monitoring for the production of technical gases
  • Replacement of extractive paramagnetic oxygen analyzers and electrochemical cells