DEWPOINT DUO™ On-Line Water and Hydrocarbon Dewpoint Analyzer

Now for the first time, incorporated within a single instrument, DEWPOINT DUO™ allows simultaneous measurement of water and hydrocarbon dewpoints. This is the most advanced instrument of its kind on the market and is the culmination of several years of research and development by ZEGAZ Instruments. Certified for use in hazardous locations. DEWPOINT DUO™ is deployed on some of the largest pipelines and gas refineries in the world. DEWPOINT DUO™ carries CSA (Class I, Div.1) and ATEX/IECEX (II 2 G Ex db IIB+H2 T6 Gb) hazardous location certifications.

Description

ZEGAZ Instruments DewPoint Duo™ water and hydrocarbon dewpoint analyzer is the most advanced dewpoint measurement system available, capable of measuring both dewpoints simultaneously.

It has an accuracy of ±0.5⁰C (±0.9 ⁰ F), distinguishes between hydrocarbon and water dewpoints and provides highly accurate, measurements. It is based on CEIRS™ (ChilledEvanescent Infrared Spectroscopy), a patented method.

ZEGAZ Instruments products are the only analyzers in the world that use CEIRS™, a spectroscopic approach that determines the dewpoint, while unambiguously determining whether it was water or hydrocarbon dewpoint. It has an accuracy of ±0.5⁰C (±0.9 ⁰ F), distinguishes between hydrocarbon and water dewpoints and provides highly accurate, measurements.

It is based on CEIRS™ (ChilledEvanescent Infrared Spectroscopy), a patented method.

 

KEY FEATURES

  • Direct, First PrincipleMeasurement
  • NIST Tested
  • No Consumables
  • Self Cleaning
  • Immune to Most Contaminants
  • Accurate and Unambiguous
  • No Calculation or Model Errors
  • Distinguishes Between Hydrocarbon and Water
  • Fully Automated
  • Works at Line Pressure
  • No Moving Parts
  • No Carrier Gas or Replacement Parts
  • Sensor Not Damaged by Contaminants, Slugs or Aerosols

 

SPECIFICATIONS

Performance

Dewpoint Measurement Range  126⁰F (70 ⁰C) below ambient temp.
Lowest Detectable Dewpoint  -40 ⁰F (-40 ⁰C)
Highest Detectable Dewpoint  +131⁰F (+55⁰C)
Measurement Time  2-12 Minutes
Dewpoint Accuracy  ±0.9 ⁰F (±0.5 ⁰C)
Dewpoint Repeatability  ±0.4 ⁰F (±0.2 ⁰C)
Dewpoint Resolution  ±0.1 ⁰F (±0.1 ⁰C)

 

Application Condition

Operating Temperature  -4 to 122⁰F (-20 to +60⁰C)
Storage Temperature  -22 to 140⁰F (-30 to +60⁰C)
Process Pressure  Up to 2000psi (135bar)
Flow Rate  0.3-1.5 SLM

 

Electrical and Communication

Input Voltage  100-264 VAC, DC Optional
Power Usage  120W Peak, <30W Average
Signal Outputs  4×4-20mA, 3xDO, RS-232, RS-485
Protocol  Modbus Gould RTU, Daniel RTU

 

Physical

Size (not including sample system)  14”x14”x6” (355x355x150mm)
Weight (not including sample system)  40lbs (18Kg)

 

Certification

Hazardous Location  CSA Class I, Div. 1, Group B,C&D, T6
Other  IP66, CE, ISO 9001