Dubai
Dubai
Abu dhabi
+971 4 3247500 Sun - Thu 08:00 - 5:30 No: FZJOA1517, JAFZA ONE PO BOX 18410, DXB
+971 2 6765979 Sun - Thu 08:00 - 5:30 P.O. Box : 33719, Abu Dhabi, UAE
Dubai
Dubai
Abu dhabi
+971 4 3247500 Sun - Thu 08:00 - 5:30 No: FZJOA1517, JAFZA ONE PO BOX 18410, DXB
+971 2 6765979 Sun - Thu 08:00 - 5:30 P.O. Box : 33719, Abu Dhabi, UAE
Leading Provider
Of Industrial Solutions
Number #1
Supplier in Middle East
Get A QuoteCatalogue

DewPort™ Portable Water and Hydrocarbon Dewpoint Analyzer

DewPort™ is the World’s only truly portable, automated, water and hydrocarbon dewpoint measurement system. It uses the patented CEIRS™ technology to accurately and simultaneously provide both water dewpoint measurements and hydrocarbon dewpoing measurements, while distinguishing between the two. Weighing at only 15 lbs (7 Kg) and using an average of less than 30W, it offers unprecedented reliability and maintenance-free operation. This product is the perfect replacement for the cumbersome-to-use manual chilled-mirrors.

Description

World’s Only Automated, Portable, Water and Hydrocarbon Dewpoint Analyzer !

  • Simultaneous Determination of Moisture and
    Hydrocarbon Dewpoints within 1 ⁰F/ (±0.5 ⁰C)
  • Inert Nature of the CEIRS™ Sensor Crystal Means
    Virtual Immunity to Contamination by Entrained
    Fluids
  • Direct, First Principal Measurement Means Modeling
    and Calculations are a Thing of the Past
  •  NIST Traceable Dewpoint Temperature Sensor
  • No Carrier Gas

KEY FEATURES

  • First Principle Chilled-mirror
    measurement
  •  Highly Reliable
  • Distinguishes Between Hydrocarbon and Water
  •  No Consumables
  •  Self cleaning
  • Immune to Most
    Contaminants
  • No Calculation Errors
  • Fully Automated

SPECIFICATIONS

Performance

Dewpoint Measurement Range  Up to 108⁰F (60 ⁰C) below ambient temp.
Lowest Detectable Dewpoint -31 ⁰F (-35 ⁰C)
Highest Detectable Dewpoint  19⁰F (10 ⁰C) below ambient temp.
Dewpoint Accuracy  ±0.9 ⁰F (±0.5 ⁰C)
User Interface  Integrated Touch-Screen Control
Measurement Time  2-15 Minutes

 

Application Condition

Operating Temperature -4 to 131⁰F (-20 to +55⁰C)
Storage Temperature  -22 to 149⁰F (-30 to +65⁰C)
Input Pressure  Up to 1500psi (103bar)
Output Pressure  25 psi
Flow Rate  2 SLM

 

Electrical and Communication

Input Voltage  9-28 VDC, AC Adapter Available
Power Usage  120W Peak, <30W Average
Battery Pack  Optional
USB Port Data Logging Last 1000 Measurements

 

Physical

Size (without sample system)  14.8”x18.7”x7” (375x475x180mm)
Weight  15lbs (7Kg)

 

Certification

Hazardous Location  General Purpose Only