MARSIC

 SICK’s MARSIC ship emissions measuring device is an innovative solution for reliably measuring emissions on ships according to MARPOL Annex VI and MEPC.184(59). MARSIC is type-approved by DNV GL for this application and measures both SOx and CO2 upstream and downstream of the scrubbers, and NOx upstream and downstream of SCR (selective catalytic reduction) plants. In addition, it can also be used for process measurements such as CH4 in LNG (liquefied natural gas) and dual-fuel engines.

Description

As a leading manufacturer of emissions measurement technology, SICK offers two variants of MARSIC. MARSIC200 has an impressive modular housing concept. MARSIC300 is available as a compact complete system. Designed to be used on ships, they boast extremely straightforward maintenance, and modules that are easy to replace.

At a glance
Tehnical Overview
Applications
Video
Downloads

  • Rugged design and high level of measurement accuracy
  • Up to four measurement points with one analyzer
  • DNV GL type approval in accordance with MARPOL Annex VI, NOx Technical Code 2008, MEPC.184(59) and MEPC.198(62)
  • Measuring ranges adapted to low and high concentrations of SO2 and NOx
  • Up to 9 measuring components simultaneously: SO2, CO2, CO, NO, NO2, NH3, CH4, H2O, and O2
Your Benefits
  • Low costs due to minimum maintenance requirements
  • No expensive test gases thanks to its internal drift correction
  • Multiple measurement points with just one analyzer
  • High levels of availability and reliability
  • Assemblies that are easy to replace during servicing
  • Servicing support is available globally
  • Quick access to expert support with remote maintenance
  • Equipped for existing and future requirements thanks to its rugged design and high level of measurement accuracy

MARSIC200 SYSTEM

Measured values CO2, SO2, NO, NO2, O2
Measurement principles NDIR spectroscopy, NDUV spectroscopy, electrochemical cell
Sample quantity
60 l/h … 100 l/h
Measuring ranges
CO2 0 … 25 Vol.-%
SO2 0 … 100 ppm / 0 … 500 ppm
NO 0 … 300 ppm / 0 … 1,500 ppm
NO2 0 … 200 ppm / 0 … 500 ppm
O2 0 … 21 Vol.-%
Response time (t90)
15 s … 30 s
Including sample gas path and gas sampling probe
Accuracy
< 1 %
Of measuring range full scale
Sensitivity drift
< 2 %: of measuring range full scale per week
Zero point drift
< 2 %: of measuring range full scale per week
Reference point drift
< 2 %: of measuring range full scale per week
Detection limit
≤ 0.5 %
Process temperature
+10 °C … +550 °C
Process pressure
–90 hPa … 200 hPa
Relative
Dust load
≤ 200 mg/m³
Ambient temperature
+5 °C … +45 °C
Storage temperature
–20 °C … +70 °C
Ambient pressure
900 hPa … 1,100 hPa
Ambient humidity
≤ 90 %
Non-condensing
Conformities MARPOL Annex VI and NTC 2008 – MEPC.177(58)

Guidelines for exhaust gas cleaning systems – MEPC.184(59)

Guidelines for SCR reduction systems – MEPC.198(62)

DNV GL Rules for Type Approvals (2012)

Electrical safety CE, DNV GL Rules
Enclosure rating
IP54
Analog outputs 8 outputs:
0 … 24 mA
Electrically isolated
Analog inputs 2 inputs:
0 … 20 mA
Digital outputs 16 outputs:
Changeover switch, 1-pin, 3 connections
Digital inputs 8 inputs:
+ 42 V
Modbus
Type of fieldbus integration TCP
Ethernet
Function Connection to OPC server
Indication
LC display
Status LEDs: “Power”, “Maintenance request” and “Fault”
Input Functional keys
Operation Via LC display or SOPAS ET software, multiple operating levels, password-protected
Model Steel sheet enclosure
Dimensions (W x H x D)
Sample conditioning

Distribution unit

Analyzer

500 mm x 560 mm x 210 mm

600 mm x 660 mm x 210 mm

550 mm x 740 mm x 319 mm

Weight
Sample conditioning 27 kg
Distribution unit 30 kg
Analyzer 37 kg
Material in contact with media PTFE, Viton B, PVDF, stainless steel 1.4571, platinum, nickel, Aluminum, CaF2, Hastelloy
Mounting Wall-mounting
Power supply
Voltage 115 V / 230 V
Different power supply via upstream transformer
Frequency 50 Hz / 60 Hz
Current consumption At 230 V AC: ≤ 8 A
Power consumption Analyzer: ≤ 300 W

Gas sampling probe: ≤ 400 W

Sample gas line, heated: ≤ 60 W/m

Sample conditioning: ≤ 150 W

Auxiliaries
Compressed air ≤ 100 l/h
Instrument air: 0.5 … 1 bar, oil content max. 0.1 mg/m³
Sample gas connections
Swagelok DN 4/6
Auxiliary gas connections
Compressed air Hose connector DN 4/6
Test gas Hose connector DN 4/6
Corrective functions Automatic zero point adjustment with N2, weekly
System components Sampling probe, heated, including filter unit

Sample gas line, partially heated

Sample conditioning

MARSIC200 distribution unit

Analyzer

Integrated components Sample gas pump

Pressure sensor

Flow sensor

Fields of applications

  • Reliable emission monitoring on ships
  • Accurate DeNOx and DeSOx measurements for ship engines
  • Cost-efficient process monitoring upstream and downstream of the scrubber and catalytic converters